william威廉亚洲官方环保
Language

Case details

Chemical and pharmaceutical industry-Anhui Xuancheng Yabang Chemical

Case details
parameter

Jiangsu Jinrun Environmental Production Engineering Co., Ltd.-Introduction of typical engineering cases-Chemical

Xuancheng Yabang Chemical Co., Ltd. (High-efficiency energy-saving stripping, ammonia removal and ammonia recovery technology)

Company name Xuancheng Yabang Chemical Co., Ltd.Unit address 70 Xuancheng Industrial Road, Anhui Province
Project scale 1200t/dayIndustry Chemical industrySign a contract 2016.12Project Acceptance 2017.6
Project nature NewContracting EPC general contractor
project name 1200 tons/day high ammonia-nitrogen wastewater treatment projectProcess flowPretreatment + BUCT-DFAT ammonium water recycling
Design Parameters(1) Design water intake index
ProjectIndexUnitWater volume
Temperature Normal temperature 1200t/d
pH ≥11.5 Dimensionless
COD ≤6000 mg/L
Calcium ion ≤3100 mg/L
Chloride ≤2500 mg/L
NH4-N 7000-8000 mg/L

(2) Design the water index
ProjectIndexUnitWater volume
pH 6-9 Dimensionless  
NH4-N ≤15 mg/L
Calcium ion ≤50 mg/L

(3) Design exhaust emission index
StandardProjectIndexUnit
GB14554-93 NH3 ≤4.9 kg/h

Notes: The Emission Standards for Odor Pollutants is executed, and the design height of the discharge chimney is 15m; organized discharge.


(4) Operational flexibility
Operation processOperating timeProduction shiftOperational flexibility
Continuous operation 8000 hours / year Three shifts in four shifts 80-110%
Process flow31.jpg

Device parameters

(5) Core process equipment parameters
NumberNameSpecificationMaterialQuantity
1Plate preheater 180m2 316L 1 station
2BUCT-DFAT tower φ2300×23000mm Q235/2205/316L 1 set
3Ammonia condenser 320㎡ 304 1 set
4Gas-liquid separator φ1800×2500mm 304 1 set
5Tail gas purification tower φ1200/1000/400×15000mm Q235/304 1 set
6Ammonium water cooler 20㎡ 304 1 station

Note: The above is the main core equipment, and the remaining facilities are not listed yet.

Economic index

(6) Economic and technical indicators of engineering
NumberNameUnitValue
1 Area m2 ≈300(Including pretreatment)
2 Installed power kw·h /
3 Operating power kw·h ≈150(Including pretreatment)
4 Water capacity m3/h 50
5 Pollutant emission reduction (NH4-N) kg/d 1800
6 Water inlet index (NH4-N) mg/L 7500
7 Water output index (NH4-N) mg/L 10
8 Steam consumption kg/t 101
9 Recovered ammonia concentration % 20
10 Recovery of ammonia water production kg/h 2206
Case real shot display

32.jpg

Factory gate

 

33.jpg

Device photos

 


扫二维码用手机看